What was found
WHILE IN AMSTERDAM FOR C CHECK, MAINTENANCE FOUND CORROSION ON FLOOR BEAM, BS 640, RBL 99. INSTALLED REPAIR PER UPS EO FILE NR B747-53-0712.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
WHILE IN AMSTERDAM FOR C CHECK, MAINTENANCE FOUND CORROSION ON FLOOR BEAM, BS 640, RBL 99. INSTALLED REPAIR PER UPS EO FILE NR B747-53-0712.