What was found
WHILE IN AMSTERDAM FOR C-CHECK, MAINTENANCE FOUND FLOORBEAM CORRODED RBL 33.99, STA 1580 FLOORBEAM OUT OF LIMITS ACC SRM 53-10-01. REPAIRED FLOORBEAM IAW SRM 53-10-07, FIG 12, AT 33.99 RBL STA 1580.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
WHILE IN AMSTERDAM FOR C-CHECK, MAINTENANCE FOUND FLOORBEAM CORRODED RBL 33.99, STA 1580 FLOORBEAM OUT OF LIMITS ACC SRM 53-10-01. REPAIRED FLOORBEAM IAW SRM 53-10-07, FIG 12, AT 33.99 RBL STA 1580.