What was found
WHILE ON GROUND, MAINTENANCE FOUND NR 4 PIT FWD UPPER RADIUS HAS .75 INCH CRACK. FABRICATED DOUBLER AS PER SRM 53-2-1, INSTALLED DOUBLER.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
WHILE ON GROUND, MAINTENANCE FOUND NR 4 PIT FWD UPPER RADIUS HAS .75 INCH CRACK. FABRICATED DOUBLER AS PER SRM 53-2-1, INSTALLED DOUBLER.