What was found
WHILE IN DALFORT FOR C-CHECK, MAINTENANCE FOUND CORROSION ON THE AFT SIDE OF THE FRAME AT STATION 1020 AND STRINGER 33L. MAINTENANCE REMOVED THE CORROSION, FABRICATED AND INSTALLED THE REPAIR ANGLE PER SRM 53-2-0, FIGURE 2B AND 51-1-21.