What was found
WHILE IN FOR D-CHECK, MAINTENANCE FOUND SPLICE FITTING CORRODED BEYOND LIMITS, LONGERON 32L AT STA 390. MAINTENANCE FABRICATED SPLICE FITTING PER SRM 51-1-20D.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
WHILE IN FOR D-CHECK, MAINTENANCE FOUND SPLICE FITTING CORRODED BEYOND LIMITS, LONGERON 32L AT STA 390. MAINTENANCE FABRICATED SPLICE FITTING PER SRM 51-1-20D.