SDR UPS804796

Service difficulty report · O-Ring · Doug DC871F

Difficulty date
October 11, 1995
Submitted
March 26, 2000
Operation
Air carrier
Aircraft
N700UP
Make and model
Doug DC871F
Aircraft serial
45900
Part
O-Ring
Condition
Failed
Location
Slot Cntrl Valve
Stage of operation
CR
Nature of condition
K, J
Precautionary procedure
H

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

CREW REPORTED HYDRAULIC SYSTEM LOST FLUID RAPIDLY IN CRUISE EMERGENCY SHUT-DOWN. HYD FLUID FELL TO STANDPIPE. FOUND O-RING BLOWN ON SLPT INLET CHECK VALVE ON SLOT CONTROL VALVE. REPLACED O-RINGS ON CHECK VALVE. LEAK CHK NORMAL PER DC8 MM 27-80-04, PG.201. CHANGED NR 3 ENG HYD PUMP AND FILTERS IAW MM 29-10-12. SERVICED HYD RESERVOIR IAW 12-30-01.