What was found
INSPECTION TYPE: D. FS 227.8, STR 19L, 2ND FASTENER LOCATION, AFT OF FRAME, WAS FOUND TO HAVE 4 INCH CRACKS IN FRAME ATTACH ANGLE (INTERCOSTAL ZERO AFTER EXISTING DOUBLER REMOVAL. REMOVED EXISTING DOUBLER AND INTERCOSTAL, FABRICATED REPLACEMENT INTERCOSTAL, INSTALLED INTERCOSTAL, AND EXISTING DOUBLER IAW SRM 51-30-2 AND 51-30-1.