What was found
INSPECTION TYPE SI, CORROSION RT NR 5 BALANCE PANEL AT MATING SURFACES OF BALANCE PANEL HINGE AND WEIGHT ASSM. REMOVED PANEL NR 5 BALANCE BAY, DRILLED OUT FASTENERS, REMOVED CORROSION FROM DOUBLER AND FOUND DOUBLER TO BE OUT OF LIMITS. FABRICATED NEW DOUBLER AND INSTALLED PANEL, BALANCE PANEL AND HINGE IN A/C PER MM 27-30-21, SRM 51-36-5 AND SRM 55-20-2.