What was found
INSPECTION TYPE SI, NR 4 K-FLAP IS CORRODED AT I/B BONDING JUMPER ATTACH POINT ON RIB. REMOVED CORROSION, REMOVED .085 FROM .170 1 BY 1 AREA OUT OF LIMITS. REMOVED CORRODED AREA, FABRICATED REPAIR PARTS AND INSTALLED RELOCATED JUMPER WIRE TO ANOTHER ATTACH POINT, ALL WORK DONE IAW SRM 57-50-01 AND 51-30-02.