What was found
INSPECTION TYPE SI, CORROSION ON MID GALLEY DOOR FWD UPPER CORNER REVEAL CORRODED. REMOVED OLD FWD UPPER REVEAL CLAMPED NEW PART IN PLACE, BACK DRILLED THROUGH EXITING FASTENER HOLES AND INSTALLED PART IAW SRM 57-30-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE SI, CORROSION ON MID GALLEY DOOR FWD UPPER CORNER REVEAL CORRODED. REMOVED OLD FWD UPPER REVEAL CLAMPED NEW PART IN PLACE, BACK DRILLED THROUGH EXITING FASTENER HOLES AND INSTALLED PART IAW SRM 57-30-02.