What was found
INSPECTION TYPE SI, CORROSION AT BS 870 VERTICAL SUPPPORT AND TIE ANGLE LBL 12 WL 199 LEFT MLG WHEEL WELL. FOUND CORROSION TO BE OUT OF LIMITS PER SRM 53-10-01. REMOVED AND REPLACED SUPPORT AND TIE ANGLE IAW SRM 53-30-02, 51-40-04, MM 51-20-31, 51-30-00.