What was found
INSPECTION TYPE: C. MCD STA 540, UPPER END AT SBL, THE BELT FRAME TO DOOR FRAME CLIP IS CRACKED. REMOVED, FABRICATED, AND INSTALLED CLIP PER DWG 69-24114 AND 51-30-2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE: C. MCD STA 540, UPPER END AT SBL, THE BELT FRAME TO DOOR FRAME CLIP IS CRACKED. REMOVED, FABRICATED, AND INSTALLED CLIP PER DWG 69-24114 AND 51-30-2.