What was found
INSPECTION TYPE SI, CORROSION ON COCKPIT ENTRY SUPPORT STA 304 WL 208 LBL 4,9 RBL 3,8 AREA MARKED. FOUND CORROSION TO BE OUT OF LIMITS PER SRM 53-10-1, FARICATED REPLACEMENT SUPPORT PER SRM 51-20-1, 51-30-8 AND 51-30-5. REPLACED FLOOR SUPPORT AT BS 304 LBL 15 PER SRM 51-30-2.