INSPECTION TYPE SI, NR 8 SLAT I/B TRACK SUPPORT STRUCTURE O/B RIB IS CRACKED IN 2 PLACES. REMOVED AND REPLACED NR 8 SLAT I/B TRACK SUPPORT FITTINGS AND WEBS PER SRM 51-30-2.