What was found
INSPECTION TYPE-C, LT WHEEL WELL O/B ANGLE BETWEEN 940 AND 950 FITTINGS AT STR 18A IS CRACKED IN TWO PLACES. REMOVED STR 18A SILL WEB, FAB'D AND INSTALLED NEW WEB PER SRM 51-10-1, 51-30-2 AND DWG 65-22419.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE-C, LT WHEEL WELL O/B ANGLE BETWEEN 940 AND 950 FITTINGS AT STR 18A IS CRACKED IN TWO PLACES. REMOVED STR 18A SILL WEB, FAB'D AND INSTALLED NEW WEB PER SRM 51-10-1, 51-30-2 AND DWG 65-22419.