What was found
INSPECTION TYPE SI, CORROSION ON FLOOR BEAM STA 680 RBL 45 TO 65 WL 208 AROUND NUTPLATE HOLES. BLEND OUT DAMAGE, FABRICATED AND INSTALLED REPAIR ANGLE IAW TRAMCO EWO 96-2427, AUTHORIZED BY UPS ENGINEERING FILE NR 727-53-1799.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE SI, CORROSION ON FLOOR BEAM STA 680 RBL 45 TO 65 WL 208 AROUND NUTPLATE HOLES. BLEND OUT DAMAGE, FABRICATED AND INSTALLED REPAIR ANGLE IAW TRAMCO EWO 96-2427, AUTHORIZED BY UPS ENGINEERING FILE NR 727-53-1799.