As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INSPECTION TYPE: SI. WHILE WORKING NRC NR 577416, FOUND CORROSION IN BARRIER NET CASTING WELL NEXT TO DRAIN HOLE STA 362 RBL 61 WL 207. REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS PER SRM 51-10-6. REMOVED AND REPLACED BARRIER NET CASTING STA 362 RBL 61 WL 207 IAW SRM'S 51-30-5, 51-30-2.