What was found
INSPECTION TYPE: SI. CORROSION AROUND NUTPLATE HOLES ON THE BL ZERO STABILIZER STRAP FROM BS 970-1166 WL 199-203. REMOVED CORRODED STABILIZER STRAP FROM BS 950-1160 AND INSTALLED NEW STABILIZER STRAP FROM BS 950-1160, ALL WORK DONE, IAW SRM'S 53-10-1, 51-30-8, 51-30-5, 51-30-2, 51-10-2, 51-10-6, MM 51-20-31.