What was found
INSPECTION TYPE: SI. CORROSION ON FRAME WEB BS 211.8 LBL 15-26 WL 165. REMOVED CORROSION FROM 211.8 FRAME WEB DOUBLER, REWORK DEEMED OUT OF LIMITS IAW SRM 53-10-1, REPLACED DOUBLER IAW SRM'S 51-30-5, 51-30-2, 51-20-1, ALSO, FOUND STIFFENERS TO BE CORRODED. REPLACED STIFFENERS IAW SAME ABOVE REFERENCES.