What was found
INSPECTION TYPE-D, LFEC INSPECTION SHOWS MATERIAL LOSS OF 10 PERCENT AT BS 259, FWD PANEL, FROM STR 19R TO 24R. FABRICATED AND INSTALLED REPAIR PER UPS EO B727-5310-1371E.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE-D, LFEC INSPECTION SHOWS MATERIAL LOSS OF 10 PERCENT AT BS 259, FWD PANEL, FROM STR 19R TO 24R. FABRICATED AND INSTALLED REPAIR PER UPS EO B727-5310-1371E.