What was found
INSPECTION TYPE-N/A, NR 2 SLAT WOULD NOT RETRACT AFTER T/O. COMPLETED AOM PROCEDURES, DUMPED FUEL AND RETURNED TO OAK. REPLACED NR 2 SLAT ACT AS PER MM 27-81-32, SLAT OPS CHKS NORMAL ON GROUND (P/N 141095-9-2) (S/N 3997L) OFF, (S/N 01405BDJLMN) ON.