What was found
INSPECTION TYPE: C. MAIN DECK FLOOR STRUCTURE, FITTING AT STA 1960 RBL 57 IS CRACKED. LENGTH OF CRACK IS 1.5 INCHES. REMOVED CRACKED FITTING AND INSTALLED NEW FITTING AT BS 1960 RBL 57 IAW SRM 51-30-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE: C. MAIN DECK FLOOR STRUCTURE, FITTING AT STA 1960 RBL 57 IS CRACKED. LENGTH OF CRACK IS 1.5 INCHES. REMOVED CRACKED FITTING AND INSTALLED NEW FITTING AT BS 1960 RBL 57 IAW SRM 51-30-02.