What was found
INSPECTION TYPE CPCP, MAIN DECK FLOOR, STRUCTURE FITTING AT BS 2060 RBL 65 IS CRACKED, LENGTH OF CRACK IS 1.5 INCH. REMOVED CRACKED FITTING AND INSTALLED NEW FITTING IAW SRM 51-30-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE CPCP, MAIN DECK FLOOR, STRUCTURE FITTING AT BS 2060 RBL 65 IS CRACKED, LENGTH OF CRACK IS 1.5 INCH. REMOVED CRACKED FITTING AND INSTALLED NEW FITTING IAW SRM 51-30-02.