What was found
INSPECTION TYPE: C. AT PRESS MAIN DECK AT BS 1265/1300 AT RBL 75, SEVERAL SPOTS CORROSION OUT OF LIMITS. REPAIRED PRESS MAIN DECK AT BS 1265 TO BS 1300 AT RBL 75 IAW SRM 53-1 0-07 FIG 2 AND IAW UPS EFN 747-53-0780.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE: C. AT PRESS MAIN DECK AT BS 1265/1300 AT RBL 75, SEVERAL SPOTS CORROSION OUT OF LIMITS. REPAIRED PRESS MAIN DECK AT BS 1265 TO BS 1300 AT RBL 75 IAW SRM 53-1 0-07 FIG 2 AND IAW UPS EFN 747-53-0780.