What was found
INSPECTION TYPE: C. EXISTING HOLE PITCH ON STR 6 BETWEEN STA 340 AND STA 360 LT HAS A SHORT FASTENER SPACING BETWEEN 9 FASTENERS. INSTALLED BACR15BB6D8 ON STR 6 BETWEEN STA 340 AND STA 360 LT ACC BOEING FAX DFX95-167.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE: C. EXISTING HOLE PITCH ON STR 6 BETWEEN STA 340 AND STA 360 LT HAS A SHORT FASTENER SPACING BETWEEN 9 FASTENERS. INSTALLED BACR15BB6D8 ON STR 6 BETWEEN STA 340 AND STA 360 LT ACC BOEING FAX DFX95-167.