INSPECTION TYPE-C, AREA AFT OF BULK CARGO COMP DURING REPLACEMENT OF FILLER FOUND CRACK IN FRAME INNERFLANGE REINFORCEMENT ANGLE AT BS 2200, NEAR FRAME STIFFENER AT S-42 RT. REPLACED REINFORCEMENT ANGLE ACCORDING TO SRM 51-30-02.