What was found
INSPECTION TYPE: C. FOUND WEB FLOOR STRUCTURE PLATE CRACKED AT BS 140 LBL 40. REPAIRED WEB FLOOR STRUCTURE PLATE BETWEEN BS 140 AND 150 LBL. 40 ACC. SRM 51-40-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE: C. FOUND WEB FLOOR STRUCTURE PLATE CRACKED AT BS 140 LBL 40. REPAIRED WEB FLOOR STRUCTURE PLATE BETWEEN BS 140 AND 150 LBL. 40 ACC. SRM 51-40-02.