What was found
INSPECTION TYPE-C, CRACK AT 1 LT DOOR ON STA 440 AT STR 26 AREA. CRACKED ANGLE REMOVED, FABRICATED NEW ANGLE SAME AS ORIGINAL PER SRM 53-10-21, NEW ANGLE INSTALLED PER SRM 51-30-02, OBTAINED FROM STA STOCK.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE-C, CRACK AT 1 LT DOOR ON STA 440 AT STR 26 AREA. CRACKED ANGLE REMOVED, FABRICATED NEW ANGLE SAME AS ORIGINAL PER SRM 53-10-21, NEW ANGLE INSTALLED PER SRM 51-30-02, OBTAINED FROM STA STOCK.