What was found
INSPECTION TYPE: C. SHEAR TIE BS 1303 BETWEEN STRS 13R AND 14R HAS FASTENER HOLES WITH IMPROPER PITCH AND SHORTED. REMOVED SHEAR TIE, FABRICATED AND INSTALLED PER SRM 53-10-2, 51-10-1, AND 51-10-2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE: C. SHEAR TIE BS 1303 BETWEEN STRS 13R AND 14R HAS FASTENER HOLES WITH IMPROPER PITCH AND SHORTED. REMOVED SHEAR TIE, FABRICATED AND INSTALLED PER SRM 53-10-2, 51-10-1, AND 51-10-2.