What was found
INSPECTION SI-CHECK, CORROSION ON BS 600 FLOOR BEAM FROM RBL 45-65 WL 208. REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS IAW SRM 53-10-1. FABRICATED AND INSTALLED REPAIR PARTS IAW EWO 97-2039 SRM 51-30-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION SI-CHECK, CORROSION ON BS 600 FLOOR BEAM FROM RBL 45-65 WL 208. REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS IAW SRM 53-10-1. FABRICATED AND INSTALLED REPAIR PARTS IAW EWO 97-2039 SRM 51-30-02.