What was found
INSPECTION TYPE-C, ON INSPECTION OF BS 740 FITTING LT, CRACK AT LWR FASTENER HOLE FOUND TO BE PROGRESSED FROM LOWER FASTENER TO END OF FITTING. *S/D* HFEC INSPECTION CARRIED OUT IAW NDT PT6 51-00-00 FIG 4. CRACK FOUND TO HAVE PROGRESSED FROM LOWER FASTENER TO END OF FITTING. BS 740 LT REPAIR CARRIED OUT IAW UPS EO B727-5310-7497-A APPENDIX B.