What was found
INSPECTION TYPE-D, SLAT 5 CRACK ON RIB AT WS 464 SLAT STA 120. CRACK APPROX .75 INCH LONG. *S/D* HFEC CARRIED OUT IAW NDT PT 6 51-00-00 FIG 4. CRACK FOUND TO BE CONTAINED WITHIN FASTENER HOLE. REPAIR CARRIED OUT IAW SRM 57-50-3 FIG 9.