What was found
INSPECTION C-CHECK, AT STA 623 LT LAP SPLICE STR 14L GOUGE FOUND TO BE OUT OF LIMITS. REMOVED DAMAGED AREA, FABRICATED AND INSTALLED FILLER AND DOUBLER IAW DHC SK-954-569 REV I.R. REF. UPS ENRG. FILE NR B727-53-1848 AND SRM 53-30-3.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION C-CHECK, AT STA 623 LT LAP SPLICE STR 14L GOUGE FOUND TO BE OUT OF LIMITS. REMOVED DAMAGED AREA, FABRICATED AND INSTALLED FILLER AND DOUBLER IAW DHC SK-954-569 REV I.R. REF. UPS ENRG. FILE NR B727-53-1848 AND SRM 53-30-3.