What was found
INSPECTION TYPE-SI, CORROSION IN WELL OF BARRIER NET CASTING BS 360 TO 380 LBL 5 WL 205. MECHANICALLY REMOVED CORROSION IAW SRM 51-10-6, REWORK IS OUT OF LIMITS IAW SRM 53-10-1, REWORKED IAW TRAMCO EWO 97-2060 UPS EO FILE NR 727-53-1857 R1.