What was found
INSPECTION TYPE: SI HFEC INSP REVEALS CRACK INDICATION BS 620 APPROX 1 INCH BELOW STR 19 LT FORWARD ROW IN FRAME CHORD INTERIOR STRUCTURE INBOARD SURFACE MARKED 12 AND 6 POSITIONS. ALL WORK ACCOMPLISHED PER UPS EO NR B727-5310-9094A.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE: SI HFEC INSP REVEALS CRACK INDICATION BS 620 APPROX 1 INCH BELOW STR 19 LT FORWARD ROW IN FRAME CHORD INTERIOR STRUCTURE INBOARD SURFACE MARKED 12 AND 6 POSITIONS. ALL WORK ACCOMPLISHED PER UPS EO NR B727-5310-9094A.