What was found
INSPECTION TYPE-SI, CREASE BEAM BROKEN AT BS 610 AND BS 625 WL 208 RBL 63. REMOVED DAMAGED AREA, FABRICATED REPAIR PARTS, TREATED PARTS AND INSTALLED PER 727 SRM 51-40-4, 51-10-2, 51-20-4, 51-30-2, MM 51-20-0.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE-SI, CREASE BEAM BROKEN AT BS 610 AND BS 625 WL 208 RBL 63. REMOVED DAMAGED AREA, FABRICATED REPAIR PARTS, TREATED PARTS AND INSTALLED PER 727 SRM 51-40-4, 51-10-2, 51-20-4, 51-30-2, MM 51-20-0.