What was found
INSPECTION TYPE:SI, CORROSION (C53-224-01.05-01) CORROSION ON FLOORBEAM AT BS 544 FROM LBL 60 TO RBL 14 WL 208. FOUND CORROSION TO BE OUT OF LIMITS PER SRM 53-10-1. REMOVED AND REPLACED FLOORBEAM IAW SRM 51-30-2, 51-10-2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:SI, CORROSION (C53-224-01.05-01) CORROSION ON FLOORBEAM AT BS 544 FROM LBL 60 TO RBL 14 WL 208. FOUND CORROSION TO BE OUT OF LIMITS PER SRM 53-10-1. REMOVED AND REPLACED FLOORBEAM IAW SRM 51-30-2, 51-10-2.