What was found
INSPECTION TYPE:SI, WHILE PERFORMING TC NR 2231 (VERTICAL TAIL TIE BEAM SPLICE INSPECTION UPPER SPLICE) DISCOVERED SPLICE TO BE CORRODED AROUND BUSHING AREAS. REMOVED VERTICAL TAIL BEAM SPLICE FABRICATED AND INSTALLED NEW BUSHINGS PER MM 27-20-141.