As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INSPECTION TYPE:SI CORROSION (C57-581-06.00-04) NR 7 FLAP TRACK FWD MOUNT HOLES HAVE CORROSION AROUND THE BUSHINGS. CORROSION OUT OF LIMITS IAW OHM 57-40-01. REPLACED NR 7 FLAP TRACK IAW SRM 51-10-1 WILL BE INSTALLED ON TC C57-581-04-4D.