What was found
INSPECTION TYPE:SI CORROSION C57-581-06-00-04 NR 6 FLAP TRACK HAS CORROSION INSIDE THE SPOILER BEAM MOUNT HOLES. CORROSION OUT OF LIMITS IAW OHM 57-40-01. REPLACED NR 6 FLAP TRACK PER SRM 51-10-1 WILL BE INSTALLED ON TC C57-581-04-4D.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:SI CORROSION C57-581-06-00-04 NR 6 FLAP TRACK HAS CORROSION INSIDE THE SPOILER BEAM MOUNT HOLES. CORROSION OUT OF LIMITS IAW OHM 57-40-01. REPLACED NR 6 FLAP TRACK PER SRM 51-10-1 WILL BE INSTALLED ON TC C57-581-04-4D.