What was found
INSPECTION TYPE-D, CORROSION AND PILLOWING SKIN (BONDED DOUBLER) ABOVE AFT LAVATORY SERVICE PANEL BS 1183 TO 1148, LBL 65 TO 67, WL 187 TO 207. CUT OUT DAMAGED SECTION OF SKIN AND BONDED DOUBLER, FABRICATED AND INSTALLED NEW SKIN SECTION, TOILET SERVICE DOOR TRIPLER, SPLICE DOUBLER AND FILLERS IAW BFG ERN 97-2637 AND UPS EO 5330-9860