What was found
INSPECTION TYPE-N/A, ON TAKEOFF ENG 1 STRUT OVERHEAT LIGHT ILLUMINATED. PER CHECK LIST, NR 1 THRUST LEVER RETARDED TO IDLE AND LIGHT WENT OUT. WHEN THRUST LEVER ADVANCED AGAIN, LIGHT RE-ILLUMINATED. LEFT THRUST IN IDLE AND RETURNED TO JAX. REMOVED NR 1 STRUT PANELS AND PERFORMED ENG RUN, NO LEAKS. CHECK WIRING AND SENSE LINE INSTALLATION. FOUND OVERHEAT LOOP RUBBING ON BRACKET. MOVED LOOP, RERAN ENGINE NR 1, NO LIGHT. REINSTALLED STRUT PANELS, OK TO CONTINUE FLIGHT.