What was found
INSPECTION TYPE-D, CORROSION IN SEVERAL AREAS OF PARTITION SUPPORT STRUCTURE (FWD LAV AT ORY) BS 342 RBL15 - RBL 60 TOP CHORD. NEW SECTION FABRICATED FROM EXTRUSION BAC 1510-355 AND FITTED IAW SRM 51-30-2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE-D, CORROSION IN SEVERAL AREAS OF PARTITION SUPPORT STRUCTURE (FWD LAV AT ORY) BS 342 RBL15 - RBL 60 TOP CHORD. NEW SECTION FABRICATED FROM EXTRUSION BAC 1510-355 AND FITTED IAW SRM 51-30-2.