What was found
INSPECTION TYPE-D, CRACK AT TOP END OF VERTICAL STIFFENER NR 4 FROM O/B ON LT SIDE ON SPANWISE BEAM NR 1 STA 820 APPROX SECOND BAY OF CENTER TANK. REPAIRED IAW SRM 51-40-4 FIG 1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE-D, CRACK AT TOP END OF VERTICAL STIFFENER NR 4 FROM O/B ON LT SIDE ON SPANWISE BEAM NR 1 STA 820 APPROX SECOND BAY OF CENTER TANK. REPAIRED IAW SRM 51-40-4 FIG 1.