What was found
INSPECTION TYPE:C, RT WING, WING GEAR WALKING BEAM FWD BEARING HOUSING SUPPORT FITTING UPPER OUTBD ATTACHMENT HOLE HAS 1 CRACK APPROX 1 INCH. REPLACED FITTING ACC KLM DFX 97-257 REV 3 APPROVED PER UPS EFN 747-57-0399.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C, RT WING, WING GEAR WALKING BEAM FWD BEARING HOUSING SUPPORT FITTING UPPER OUTBD ATTACHMENT HOLE HAS 1 CRACK APPROX 1 INCH. REPLACED FITTING ACC KLM DFX 97-257 REV 3 APPROVED PER UPS EFN 747-57-0399.