What was found
INSPECTION TYPE: C. NR 1 PIT STA 260-270 AT STR 33L INTERCOASTAL BETWEEN FRAMES HAS A HOLE AND 2 CRACKS IN RADIUS. REMOVED DAMAGE, FABRICATED AND INSTALLED REPAIR IAW SRM 53-2-0.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE: C. NR 1 PIT STA 260-270 AT STR 33L INTERCOASTAL BETWEEN FRAMES HAS A HOLE AND 2 CRACKS IN RADIUS. REMOVED DAMAGE, FABRICATED AND INSTALLED REPAIR IAW SRM 53-2-0.