INSPECTION TYPE-C, AFT TEE CHORD SPLICE STA 1690 LBL 12 SEVERLY EXFOLIATED. REMOVED EXISTING SPLICE, FABRICATED REPLACEMENT SPLICE ANGLE IAW DWG 3642778, DRILLED AND INSTALLED IAW SRM 51-30-1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE-C, AFT TEE CHORD SPLICE STA 1690 LBL 12 SEVERLY EXFOLIATED. REMOVED EXISTING SPLICE, FABRICATED REPLACEMENT SPLICE ANGLE IAW DWG 3642778, DRILLED AND INSTALLED IAW SRM 51-30-1.