What was found
INSPECTION TYPE-D, STA 717 FRAME FITTING BELOW FLOOR IS CRACKED AT THE LOWER END LT SIDE O/B. REMOVED, FABRICATED AND INSTALLED REPLACEMENT FITTING PER SRM 51-1-20 DWG 3616947 AND DHC SK-748-110.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE-D, STA 717 FRAME FITTING BELOW FLOOR IS CRACKED AT THE LOWER END LT SIDE O/B. REMOVED, FABRICATED AND INSTALLED REPLACEMENT FITTING PER SRM 51-1-20 DWG 3616947 AND DHC SK-748-110.