What was found
INSPECTION TYPE: C. C-3 LOWER CARGO PIT LT FORWARD FLOOR TRACK CORRODED 2 EACH PLACES. REMOVED, FABRICATED AND INSTALLED REPLACEMENT TRACK FROM STA 1078 TO 1140 IAW SRM'S 53-2-3 AND 57-3-0.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE: C. C-3 LOWER CARGO PIT LT FORWARD FLOOR TRACK CORRODED 2 EACH PLACES. REMOVED, FABRICATED AND INSTALLED REPLACEMENT TRACK FROM STA 1078 TO 1140 IAW SRM'S 53-2-3 AND 57-3-0.