What was found
INSPECTION TYPE-C/CK, CABIN FLOORBEAM STA 700 BOTTOM SIDE OF UPPER CHORD AT SEAT TRACK-G CRACK AT FASTENERS. REMOVED FASTENERS, REMOVED CORROSION IAW DC8 SRM 51-1-8. PERFORMED DYE PEN TEST ON FLOORBEAM, FOUND NO CRACKS. ALODINED AND PRIMED AREA IAW DC8 SRM D51-1-8. INSTALLED FASTENERS IAW DC8 SRM D51-3-0.